Apex

Indirect Fired Heater

Apex , Well Testing has developed its own set of fabrication specifications to ensure that equipment used by Apex Petroleum Services, Well Testing meets or exceeds all local requirements. Apex Petroleum Services, Well Testing specifications are primarily based on the following worldwide recognised specifications:

Equipment Design and Fabrication Specifications

  • API Spec 6A – Specification for Valves and Wellhead Equipment
  • ASME VIII For construction of pressure vessels , Div 1&2
  • API RP 14C – Recommended Practice for Analysis, Design, Installation, and Testing of Basic Surface Safety Systems on Offshore Production Platforms
  • NACE MR-01-75
  • Product Specification Level (PSL) 3
  • Material Class DD
  • Temperature Class P&X (-20° F to +350° F)

Indirect Fired Heater

Water Bath Heaters are designed to heat high-pressure fluids and gas coming from the well or pipeline. Water bath heaters (water jacket furnace) are used in the oil and gas industry for heating the medium of the pipeline to prepare for further technological needs. It is also called an indirect bath heater.

The configuration of the heater may differ depending on the process application. Usually, the heater consists of a main body with coil tubes, a burner, a firetube, and a flue stack. Sometimes, a skid may include an expansion tank.

Main Body:

The main body refers to the basic vessel into which the firetubes and process coils are inserted from opposite ends. The burner ignites the fuel gas or fuel oil and blows it into the firetube to heat the water in the vessel, and the hot water heats the medium in the coils, such as crude oil or raw natural gas. The process coils are “bathing” in the water, and that’s why it’s called a water bath heater.

Outlet Temperature:

The outlet temperature may vary, but usually doesn’t exceed 86-88 °C.

Features and Benefits

  • Features a split-coil design, which allows more efficient thermal conductivity and reduced pressure drop through the coil package.
  • Features a modular design with a box beam container, which conforms to ISO specifications for improved portability.
  • Available for gas-fired, oil-fired, and electric for maximum flexibility.
  • Has a bypass manifold, which helps during cleanup by reducing damage to coils.
  • Equipped with built-in control and safety shutdowns as an integral part of the design.
  • Meets applicable industry standards.
  • Can be third-party certified.

Operation

Indirect-gas or diesel-fired heaters consist of a large, low-pressure tank that contains water or glycol heated by a gas or diesel burner in a tube. The fluid to be heated passes through high-pressure flow tubes or coils, which are installed in the tank and covered by water or glycol. The coils make multiple passes inside the tank to provide the largest amount of surface area possible for heat transfer.

All Apex heaters incorporate a split-coil design with preheat and post-heat coils. The preheat coils heat the well effluent before it passes through a choke. The post-heat coils reheat the well effluent after it has passed through the choke.

Indirect Fired Heater

Indirect-Fired Heater Specifications

Capacity Btu/hr2 million Oil Fired3 million Oil/Gas Fired3 million Oil/Gas Fired
Pressure Rating (psi) (bar)5,000 (344.74)5,000 (344.74)10,000 (689.48)
Preheat Coils14-3-in. XXH16-3-in. XXH14-4-in. OD x 2.5-in. ID
Preheat Coils Rating psi (bar)5,000 (344.74)5,000 (344.74)10,000 (689.48)
Post-heat Coils8-4-in. XH10-4-in. XH8-4-in. XH
Post-heat Coils Rating psi (bar)2,000 (137.90)2,000 (137.90)2,000 (137.90)
Choke psi (bar)2 in. 5,000 (344.74)2 in. 5,000 (344.74)2 in. 10,000 (689.48)
ServiceH2S*H2S*H2S*
Heater OD (in. cm)68 (122)72 (183)72 (183)
Skid Length (in. cm)359.25 in. (912)359.25 in. (912)359.25 in. (912)
Skid Width (in. cm)96 (244)96 (244)96 (244)
Skid Height (in. cm)114 (290)114 (290)114 (290)
Skid Weight (lb. kg)30,000 (13,608)37,000 (16,783)38,000 (17,237)
Inlet3 1/8-in. 5K c/w 3-in. 602 (T) XO3 1/8-in. 5K 3-in. 602 HU (T) XO2 9/16-in. 10K 3-in. 1502 (T) XO
Outlet3 1/8-in. 5K R35 c/w 3-in. 602 (W) XO4-in. – 900 lb RTJ c/w 4-in. 602 (W) XO4-in. – 900 lb RTJ c/w 4-in. 602 (W) XO
Drain2-in. – 150 lb2-in. – 150 lb2-in. – 150 lb

*Meets requirements of NACE MR-01-75

Note:

Other sizes, configurations, and pressure ratings are available to meet most applications. These ratings are guidelines only. For more information, contact your local Apex representative.